Skip to main content

Table 2 Iron dextran removal by high-flux or high-efficiency hemodialysis membranes over 240 minutes. (System A)

From: Determination of iron sucrose (Venofer) or iron dextran (DexFerrum) removal by hemodialysis: an in-vitrostudy

  Iron Dextran (DexFerrum®)
Study condition SBS % iron concentration change
(mean ± SD)
Khd (hr-1)
(mean ± SD)
Dialysate Iron Recovery (mg)
(mean ± SD)
Clearance (ml/min)
(mean ± SD)
F80: 0 ml/hr UFR -9.69 ± 3.31 -0.0004 ± 0.0001 0.00 ± 0.00 -2.29 ± 0.75
F80: 500 ml/hr UFR -7.84 ± 0.73 -0.0003 ± 0.0000 0.00 ± 0.00 -1.26 ± 0.11
CA210: 0 ml/hr UFR -8.77 ± 6.76 -0.0003 ± 0.0003 5.44 ± 7.70 -2.06 ± 1.54
CA210: 500 ml/hr UFR -7.48 ± 3.54 -0.0003 ± 0.0001 0.00 ± 0.00 -1.20 ± 0.55
  1. SBS = simulated blood solution; UFR = ultrafiltration rate; Khd = hemodialysis elimination rate; % = percent; † = Clearance values that are positive relate to accumulation of substance from the system; negative clearance values represent removal of substance