Skip to main content

Table 6 Validation group: Correlations, bias, precision and accuracy of the different GFR prediction methods and measured 24hU-CrCl without statistical single data point outlier

From: Quantification of excretory renal function and urinary protein excretion by determination of body cell mass using bioimpedance analysis

  

Correlation coefficient R

SEE

BIAS median difference

ABSOLUTE BIAS

PRECISION IQR (P25, P75) of differences

ACCURACY

P15 (%)

P30 (%)

All subjects (N = 30)

mCrCl

0.972***

9.0

0.1

4.3

6.9 (-4.4, 2.5)

27 (90)a

30 (100)bcd

4vMDRD

0.974***

8.7

−8.6

8.6

14.4 (-19.7, -5.3)

8 (27)

17 (57)

CKD-EPI

0.974***

8.7

−7.1

7.1

12.9 (-17.1, -4.2)

9 (30)

17 (57)

CG-CrCl

0.971***

9.3

−4.8

6.6

9.1 (-9.0, 0.1)

17 (55)

28 (93)

Female (N = 15)

mCrCl

0.952***

5.6

−0.6

1.8

6.3 (-4.2, 2.1)

14 (93)

14 (93)

4vMDRD

0.951***

4.8

−6.4

6.4

6.1 (-10.3, -4.2)

5 (33)

11 (73)

CKD-EPI

0.929***

6.7

−5.3

5.3

6.2 (-8.8, -2.7)

5 (33)

11 (73)

CG-CrCl

0.952***

6.7

−1.6

2.8

8.0 (-6.2, 1.8)

8 (53)

13 (87)

CrCl > 60 (N = 10)

mCrCl

0.638*

14.0

−0.4

11.5

15.3 (-11.7, 3.5)

9 (90)

10 (100)

4vMDRD

0.668*

13.6

−23.2

23.2

21.4 (-35.3, -13.9)

2 (20)

8 (80)

CKD-EPI

0.660*

13.7

−18.7

18.7

22.3 (-25.8, -3.5)

4 (40)

10 (100)

CG-CrCl

0.771**

11.6

−8.7

8.7

14.9 (-20.6, -5.7)

4 (40)

10 (100)

BMI > 30 (N = 7)

mCrCl

0.995***

5.2

−0.4

1.5

(-15.5, 1.5)††

7 (100)

7 (100)

4vMDRD

0.991***

7.4

−10.5

10.5

(-42.0, -4.2)††

0

3 (43)

CKD-EPI

0.995***

5.4

−9.1

9.1

(-34.0, -4.2)††

0

6 (86)

CG-CrCl

0.987***

8.9

−7.1

7.1

(-26.6, 6.1)††

4 (57)

7 (100)

  1. ***p < 0.001; **p < 0.01; *p < 0.05;
  2. displayed in mL/min/1.73 m2; ††(Minimum, Maximum)
  3. ap < 0.005 vs the three other methods; bp = 0.12 vs 4vMDRD; cp = 0.34 vs CKD-EPI; dp = 0.8 vs CG