Table 1 Measurement of normal renal elasticity by shear wave elastography (SWE)

From: Effect of renal perfusion and structural heterogeneity on shear wave elastography of the kidney: an in vivo and ex vivo study

Position

Compartments

Left kidney (kPa, n = 16)

Right kidney (kPa, n = 16)

P value

Renal mid-portion

Cortex

15.78 ± 1.52**##

16.33 ± 1.44**##

0.382

Medulla

13.16 ± 1.69*

13.55 ± 1.38*

0.561

Sinus

11.70 ± 1.62

12.23 ± 1.42

0.432

Renal lower pole

Cortex

4.41 ± 0.36

4.50 ± 0.48

0.54

  1. Values are given as the mean ± SD. Measurements were performed respectively with the ultrasound (US) beam along (axial, mid-portion) and perpendicular (transverse, lower pole) to the main axis of the pyramid. Using paired t-test or ANOVA analysis. Compared with sinus: *, P<0.05; **, P<0.01 Compared with medulla: ##, P<0.01