Skip to main content

Table 2 Hazard ratio’s for primary and secondary outcomes

From: The best solution down the line: an observational study on taurolidine- versus citrate-based lock solutions for central venous catheters in hemodialysis patients

Endpoint / Lock type

Events

Patients

HR

95%CI

p-value

Primary outcome

 Citrate 4% or 30%

68

308

Ref.

 Citrate 46.7%

239

1110

0.96

0.73–1.26

0.76

 Taurolidine

12

96

0.34

0.19–0.64

< 0.001

Secondary outcome – infection

 Citrate 4% or 30%

30

308

Ref.

 Citrate 46.7%

120

1110

1.10

0.74–1.64

0.64

 Taurolidine

6

96

0.36

0.15–0.88

0.02

Secondary outcome – catheter malfunction

 Citrate 4% or 30%

38

308

Ref.

 Citrate 46.7%

119

1110

0.85

0.59–1.23

0.39

 Taurolidine

6

96

0.33

0.14–0.79

0.01

  1. Ref. indicates reference catgory