Skip to main content

Table 3 Meta-analysis results of the combination of risk factors for CRI

From: A meta-analysis of risk factors for a Dacron-cuffed catheter related infection in hemodialysis

Risk factors

Number of studies

Heterogeneity test

Model

OR

95% CI

p-value

I2(%)

p-value

Combined with diabetes

11

61

0.00500

Random

1.96

1.56 ~ 2.48

 < 0.00001

Hb level

8

91

 < 0.00001

Random

1.82

1.35 ~ 2.45

 < 0.00010

Age

5

96

 < 0.00001

Random

2.38

1.06 ~ 5.34

0.04000

Catheter indwelling time

6

86

 < 0.00001

Random

1.79

1.21 ~ 2.66

0.00400

Serum albumin level

5

90

 < 0.00001

Random

2.26

1.25 ~ 4.08

0.00700

Femoral vein catheter

2

0

0.88000

Fixed

3.29

1.74 ~ 6.23

0.00030

Catheterization times

2

27

0.24000

Fixed

5.40

2.65 ~ 11.02

 < 0.00001