Creatinine clearance in selection of living kidney donor among the Malaysian population: is it safe?

Abstract

Background

Assessment of donor renal function is made by the measurement of Glomerular Filtration Rate (GFR). Exogenous markers are preferred over creatinine clearance and are widely used for measuring GFR. However, they are difficult to obtain, costly and laborious. This is a study to look into the safety and accuracy of creatinine clearance for renal assessment among the living kidney donors in the Malaysian population.

Methods

This is a retrospective, single-centre study comprising 105 living kidney donor candidates from the year 2007 to 2020. By comparing against 51-Chromium ethylenediamine-tetraacetic acid (51Cr-EDTA), we analysed creatinine clearance for correlation, bias, precision and accuracy.

Results

The study group had a mean age of 45.68 ± 10.97 years with a mean serum creatinine of 64.43 ± 17.68 µmol/L and a urine volume of 2.06 ± 0.83 L. Mean measured GFR from 51Cr-EDTA was 124.37 ± 26.83 ml/min/1.73m2 whereas mean creatinine clearance was 132.35 ± 38.18 ml/min/1.73m2. Creatinine clearance overestimated 51Cr-EDTA significantly with a correlation coefficient of 0.48 (p < 0.001) and an accuracy of 78.10% and 64.0% within 30% and 20% respectively of 51Cr-EDTA.

Conclusion

Creatinine clearance is an acceptable and affordable alternative for donor renal assessment in the absence of exogenous markers with an emphasis on adequate urine collection followed by using measured GFR in selected cases.

Peer Review reports

Background

From 2007 to 2016, there were a total of 1130 renal transplants in Malaysia, of which 426 were living-related renal transplants [1]. All living kidney donors undergo a series of workups prior to transplants and this includes assessment of renal function in the form of Glomerular Filtration Rate (GFR). An accurate assessment of GFR is important to minimize risks to the potential living kidney donor.

The gold standard for GFR assessment is by the measurement of urinary clearance of inulin. Other alternative exogenous markers include Chromium 51 ethylenediamine-tetraacetic acid (51Cr-EDTA), iothalamate, and iohexol. Of these, 51Cr-EDTA is well-recognized and one of the most widely used marker in the measurement of GFR [2]. However, these substances are difficult to obtain in Malaysia and their use are hampered by cost factors and laboriousness. Measuring creatinine clearance (CrCl) by means of 24-hour urine collection is an alternative when exogenous filtration markers are not available [3]. However, CrCl may be affected by overestimation or underestimation due to errors in urine collection as well as from the tubular secretion of creatinine [3,4,5,6,7,8].

There have been studies comparing various methods in measured GFR (mGFR) among potential living kidney donors and most have demonstrated superiority of using exogenous markers in comparison to creatinine clearance [4]. Nevertheless, there is a considerable variation of GFR evaluation among the transplant centres across the world [9, 10]. However, there is a lack of local data on the donor renal assessment in our country. Thus, this is a study to look into the safety and accuracy of CrCl against 51Cr-EDTA in measuring GFR among the living donors in Malaysian population in regards to feasibility as a first line agent.

Methods

This is a retrospective, single-centre study. We looked into all adults aged 18 years and above who were potential living kidney donors from the year 2007 to 2020 with both measured GFR using 51Cr-EDTA and CrCl performed at the University of Malaya Medical Centre (UMMC).

A total of 180 living related adult kidney donors that underwent workups between the year 2004 and 2020 were recruited into the study. Each of these patients has up to 3 consecutive paired serum and urine creatinine samples and a 51Cr-EDTA measurement. Exclusion criteria include absence of serum/urine creatinine, absence of 51Cr-EDTA and inadequate 24-hour urine collection. For a 24-hour urine sample to be considered adequate, a general rule of urine creatinine ranging 177 to 221 µmol/kg/day for male and 133 to 177 µmol/kg/day for female was implemented across all ages [11]. 75 subjects (41.7%) were excluded due to inadequate urine sample using this criterion. Data collected from Electronic Medical Record (EMR) also included age, gender, race, weight, height, and Body mass index (BMI). Laboratory values include serum creatinine, 24-hour urine creatinine, and volume of urine.

Following a single intravenous administration of 51Cr-EDTA, blood was sampled at 2, 2.5, 3 and 4 h. Calculation of mGFR was performed using the slope-intercept method. Serum creatinine was determined by isotope dilution mass spectrometry reference-modified Jaffe kinetic assay (CrJaffe). Creatinine clearance (CrCl) was calculated using the formula:

$$\text{C}\text{r}\text{C}\text{l}(ml/\text{m}\text{i}\text{n})=\frac{{U}_{Cr}(mmol/24hr)\times Volume(ml/24hr)}{{S}_{Cr}(mmol/hr)\times 1440(min/24hr)}$$

where UCr represents urine creatinine and SCr represents serum creatinine. The resulting GFR from both 51Cr-EDTA and CrCl were adjusted to a body surface area of 1.73m2. BSA is determined using Du Bois Method [12]:

$$\text{B}\text{S}\text{A}=0.007184\times {\text{h}\text{e}\text{i}\text{g}\text{h}\text{t}}^{0.725}\times {\text{w}\text{e}\text{i}\text{g}\text{h}\text{t}}^{0.425}$$

Clinical data was statistically analysed using Statistical Package for the Social Sciences (SPSS) software (version 25.0; SPSS Inc., Chicago, IL, USA). A p-value of less than 0.05 is considered statistically significant. The data are shown as mean ± standard deviation (SD). To make a comparison between 51Cr-EDTA and CrCl, the correlation coefficient (r) was determined. The bias, precision, and accuracy within 30% and 20% of 51Cr-EDTA were also established. Bias was defined as the mean difference between CrCl and 51Cr-EDTA while precision of the CrCl is expressed as standard deviation of the mean difference between CrCl and 51Cr-EDTA. Accuracy between CrCl and 51Cr-EDTA incorporates both bias and precision and was expressed as percentage of CrCl falling within 30% and 20% respectively of 51Cr-EDTA.

The Bland-Altman plot were used as a graphical depiction of the above, where the bias was charted against the mean of the two methods. In another different approach, a modified Bland-Altman plot where 51Cr-EDTA, which is considered as a reference method, was portrayed on the x axis rather than using mean of 51Cr-EDTA and CrCl. The diagram is an alternative approach when one of the methods is considered more accurate [13].

Results

Table 1 shows the baseline characteristics. The study group had a mean age of 45.68 ± 10.97 years with a mean serum creatinine of 64.43 ± 17.68 µmol/L and a urine volume of 2.06 ± 0.83 L. Female comprised 72.4% of the donors while Chinese, Malay and Indian made up 63.8%, 21.9% and 9.5% of the donors respectively. Mean mGFR from 51Cr-EDTA was 124.37 ± 26.83 ml/min/1.73m2 whereas mean CrCl was 132.35 ± 38.18 ml/min/1.73m2.

Table 1 Baseline characteristics

The mean absolute bias between CrCl and 51Cr-EDTA was 7.98 ml/min/1.73m2 (8.7%) with a correlation coefficient (r) of 0.48. CrCl significantly overestimated 51Cr-EDTA (p < 0.001) (Fig. 1). This finding did not come as surprise as creatinine clearance is known to overestimate mGFR. However, the precision shown by CrCl in our study was suboptimal at 36.95 ml/min/1.73m2. The accuracy of CrCl within 30% of 51Cr-EDTA was 78.10%, but it dropped slightly to 61.0% when the accuracy within 20% of 51Cr-EDTA was used.

Fig. 1
figure 1

Relationship between 51Cr-EDTA and CrCl. The correlation coefficient is 0.48

To further illustrate the difference between 51Cr-EDTA and CrCl, the Bland and Altman plot was used. This is a scatter plot (Fig. 2) that displays the span between − 2SD and + 2SD of the mean difference (limit of agreement that represents 95% confidence interval). Using the modified Bland and Altman plot (Fig. 3), we are able to appreciate that when CrCl is at a much higher reading than 51Cr-EDTA (beyond the threshold for kidney transplant) it is less accurate. The same cannot be said when CrCl is lower than its counterpart.

Fig. 2
figure 2

Bland and Altman plot whereby the differences are plotted against the mean between CrCl and 51Cr-EDTA. The solid line represents the mean difference (bias) while the dashed lines indicate ± 1.96 standard deviations (SD)

Fig. 3
figure 3

Modified Bland-Altman plot whereby the differences between CrCl and 51Cr-EDTA are plotted against 51Cr-EDTA (reference method) to visualize bias and accuracy. Accuracy within 30% (P30)(dotted lines) and 20% (P20)(dashed lines) of 51Cr-EDTA are shown

Discussion

It is vital for donor renal assessment to be determined as accurately as possible. Malaysia has an incidence rate of renal transplantation of 3 to 5 per million population, which is very low in comparison to countries like Australia and New Zealand with a rate 27 to 37 per million population [1]. As Malaysia aims for a higher rate of living-related renal transplant, a precise assessment of GFR minimizes the long-term risks to the donors post-transplant. While Ibrahim et al. found that the survival and risk of end-stage kidney disease (ESKD) in a carefully screened donors are similar to the general population, in a longer follow up study done by Mjoen et al., they observed that kidney donors have a higher risk of cardiovascular deaths, ESKD and all-cause mortality [14, 15].

Clearance of chromium 51-labeled ethylenediaminetetraacetic acid (51Cr-EDTA) remains one of the most commonly used exogenous markers as an indirect measurement of GFR. Despite being more obtainable than inulin, 51Cr-EDTA remains scarce in Malaysia and it is also costly and technically more difficult to perform compared to CrCl. 51Cr-EDTA however, has a good accuracy of mGFR and this is shown by a systematic review of mGFR that compared 14 studies of 51Cr-EDTA against the reference method [4].

An mGFR of less than 80 ml/min/1.73m2 is excluded from kidney donation, which is important for donor outcome [16]. 24-hour urine collection for creatinine clearance remains the most common method for GFR assessment when the exogenous markers are not widely available. However, CrCl is fraught with reports of over and underestimation of GFR. KDIGO reports a magnitude of overestimation of 15% or more at normal GFR, based on older data using non-standardized serum creatinine assays [3]. Soveri et al., in their systematic review of mGFR found that CrCl overestimated renal inulin clearance of which 16 studies were of high quality [4].

Our study findings showed that CrCl had a significantly higher mean than using 51Cr-EDTA; which is in agreement with other similar studies that compared CrCl to the reference method [4, 5, 7, 8]. There were several plausible explanations for the overestimation. The most well-known circumstance would be the tubular secretion of creatinine, especially at higher readings of CrCl often encountered in healthy donors, which was also reflected on our data. Another recognised factor may come from inaccuracies in urine collection. We took into consideration on the adequacy of urine collection by gender and body weight to minimize sampling errors [11]. In this study, the adequacy was defined as urinary excretion of creatinine between 177 and 221 µmol/kg/day for male and 133 to 177 µmol/kg/day for female for all ages. However, it is also known that beyond 50 years of age, these figures progressively declines and thus in older candidates, there might be an overcollection leading to overestimation of mGFR.

Undeniably, by implementing the criteria of adequacy, only 58.3% of the donors had urine samples that were sufficient. The large proportion of donors with inadequate urine samples may reflect the lack of patient understanding of the urine collection procedure. Other reasons include loss of specimen from a poorly sealed container and incorrect storage at room temperature [17]. Indeed, our findings of inaccuracy were similar to the quoted rate of about 50% in other literatures. McGuire and colleagues found that 51% of patients had inaccurate urine collection while Sawyer and associates reported inaccurate urine sampling in 50.7% of their patients [18, 19].

To date, this is the first head to head study comparing the CrCl against 51Cr-EDTA. Despite the above shortcomings, it is important to note that CrCl in our study remained significantly concordant with 51Cr-EDTA with a reasonable accuracy within 20% and 30% of 51Cr-EDTA. By the above principles, it is probably acceptable in terms of utilizing CrCl for other purposes e.g. adjustments of dosage of medications. However, mGFR using CrCl for donor selection may have different implications as there exists a cutoff point for mGFR to be considered for donation. For example, if a potential kidney donor has a mGFR of 80 ml/min/1.73m2 using CrCl, it may be possible that the actual GFR may be lower. Reassuringly, from our study this is only observed at much higher levels of CrCl that is more than sufficient to be eligible for donation.

Even so, to address the overestimation of GFR by CrCl, we could potentially look into including urea and creatinine clearance in a single 24-hour collection [20]. We could also look into using cimetidine to improve the reliability of CrCl [21]. There were other limitations as well. Firstly, this is a retrospective single centre study with a small sample size. However, the study cohort has a multiracial composition which is in line with the multiethnicity in Malaysia. The inclusion of adequacy of urine collection also proved to have both favourable and unfavourable consequences as a large proportion of donors with inadequate urine samples were excluded from the analysis so as not to affect the validity of the study as well as the issue of possible overestimation in older donor candidates.

Conclusion

The results of our study highlighted that CrCl is an acceptable and affordable alternative for donor GFR assessment with an emphasis on adequate urine collection. Taking into account on the overestimation bias, precision and accuracy, it is recommended for those with a CrCl below 100 ml/min/1.73m2 to proceed with mGFR using exogenous markers.

Availability of data and materials

The data that support the findings of this study are available on request from the corresponding author, KPN. The data are not publicly available as they contain information that could compromise the privacy of the participants.

Abbreviations

51Cr-EDTA:

51-labeled ethylenediaminetetraacetic acid

BSA:

Body Surface Area

BMI:

Body Mass Index

CrCl:

Creatinine clearance

ESKD:

End Stage Kidney Disease

GFR:

Glomerular Filtration Rate

mGFR:

Measured Glomerular Filtration Rate

SCr :

Serum Creatinine

SD:

Standard Deviation

SPSS:

Statistical Package for the Social Sciences

UCr :

Urine Creatinine

References

  1. Wong H, Goh B, Ghazali A, Lim Y, Lui W, Lee MJMNRR. 24th report of the Malaysian Dialysis and Transplant Registry 2016. 2018, 24:1–263. https://www.msn.org.my/nrr/24th-report-of-the-malaysian-dialysis-and-transplant-registry-2016/.

  2. Fleming JS, Wilkinson J, Oliver RM, Ackery DM, Blake GM, Waller DG. Comparison of radionuclide estimation of glomerular filtration rate using technetium 99m diethylenetriaminepentaacetic acid and chromium 51 ethylenediaminetetraacetic acid. Eur J Nucl Med. 1991;18(6):391–5.

    Article  CAS  PubMed  Google Scholar 

  3. Lentine KL, Kasiske BL, Levey AS, Adams PL, Alberu J, Bakr MA, Gallon L, Garvey CA, Guleria S, Li PK, et al. KDIGO Clinical Practice Guideline on the evaluation and care of living kidney donors. Transplantation. 2017;101(8S Suppl 1):1–S109.

    Google Scholar 

  4. Soveri I, Berg UB, Björk J, Elinder CG, Grubb A, Mejare I, Sterner G, Bäck SE, Group SGRJAjokd. Measuring GFR: a systematic review. Am J Kidney Dis. 2014;64(3):411–24.

    Article  PubMed  Google Scholar 

  5. Issa N, Meyer KH, Arrigain S, Choure G, Fatica RA, Nurko S, Stephany BR, Poggio ED. Evaluation of creatinine-based estimates of glomerular filtration rate in a large cohort of living kidney donors. Transplantation. 2008;86(2):223–30.

    Article  CAS  PubMed  Google Scholar 

  6. Chung BH, Yu JH, Cho HJ, Kim JI, Moon IS, Park CW, Yang CW, Kim YS, Choi BS. Comparison of estimating equations for the prediction of glomerular filtration rate in kidney donors before and after kidney donation. PLoS One. 2013;8(4):e60720.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  7. Kakuta Y, Okumi M, Ichimaru N, Abe T, Nonomura N, Okuyama A, Kojima Y, Isaka Y, Takahara S, Imai E, et al. Utility of the Japanese GFR estimation equation for evaluating potential donor kidney function. Clin Exp Nephrol.  2010;14(1):63–7.

    Article  CAS  PubMed  Google Scholar 

  8. Macías L, Poblet M, Pérez N, Jerez R, Roncero FG, Blanco G, Valdivia M, Benjumea A, Govantes MG. Assessment of the renal function in potential donors of living kidney transplants: Expanded study. Transplant Proc 2015. 2015;47:2603–7 Elsevier.

    Google Scholar 

  9. Mandelbrot DA, Pavlakis M. Living donor practices in the United States. Adv Chronic Kidney Dis. 2012;19(4):212–9.

    Article  PubMed  PubMed Central  Google Scholar 

  10. Andrews PA, Burnapp L. British Transplantation Society/Renal Association UK guidelines for living donor kidney transplantation 2018: summary of updated guidance. Transplantation. 2018;102(7):e307.

    Article  PubMed  PubMed Central  Google Scholar 

  11. Inker LA, Levey AS. Assessment of glomerular filtration rate in acute and chronic settings. National Kidney Foundation Primer on Kidney Diseases.edn. Philadelphia: Elsevier; 2014. p. 26–32.

  12. Du Bois D. A formula to estimate the approximate surface area if height and weight be known. Nutrition. 1989;5:303–13.

    PubMed  Google Scholar 

  13. Krouwer JS. Why Bland-Altman plots should use X, not (Y + X)/2 when X is a reference method. Stat Med. 2008;27(5):778–80.

    Article  PubMed  Google Scholar 

  14. Ibrahim HN, Foley R, Tan L, Rogers T, Bailey RF, Guo H, Gross CR, Matas AJ. Long-term consequences of kidney donation. N Engl J Med. 2009;360(5):459–69.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  15. Mjøen G, Hallan S, Hartmann A, Foss A, Midtvedt K, Øyen O, Reisæter A, Pfeffer P, Jenssen T, Leivestad T. Long-term risks for kidney donors. idney Int. 2014;86(1):162–7.

    Google Scholar 

  16. Delmonico F. A report of the Amsterdam Forum on the care of the live kidney donor: data and medical guidelines. Transplantation. 2005;79(6 Suppl):S53-66.

    PubMed  Google Scholar 

  17. Rabinovitch A, Sarewitz S, Woodcock S, Allinger D, Azar M, Dynek D, Rabinovitch M, Stade BJCNNDG-A. Urinalysis and collection, transportation, and preservation of urine specimens: approved guideline. 2001.

  18. McGuire BB, Bhanji Y, Sharma V, Frainey BT, McClean M, Dong C, Rimar K, Perry KT, Nadler RB. Predicting patients with inadequate 24-or 48-hour urine collections at time of metabolic stone evaluation. J Endourol. 2015;29(6):730–5.

    Article  PubMed  Google Scholar 

  19. Sawyer MD, Dietrich MS, Pickens RB, Herrell SD, Miller NL. Adequate or not? A comparison of 24-hour urine studies for renal stone prevention by creatinine to weight ratio. J Endourol. 2013;27(3):366–9.

    Article  PubMed  Google Scholar 

  20. Traynor J, Mactier R, Geddes CC, Fox JG. How to measure renal function in clinical practice. BMJ. 2006;333(7571):733–7.

    Article  PubMed  PubMed Central  Google Scholar 

  21. Hilbrands LB, Artz MA, Wetzels JF, Koene RA. Cimetidine improves the reliability of creatinine as a marker of glomerular filtration. Kidney Int. 1991;40(6):1171–6.

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgements

Special thanks to the staffs of Division of Nephrology, Department of Medicine, University of Malaya Medical Centre for the contribution and support of this study.

Funding

This research received no specific grant from any funding agency in the public, commercial, or not-for-profit sectors.

Author information

Authors and Affiliations

Authors

Contributions

CK and YW are the main investigators responsible for the execution the study, data collection and analysis as well as drafting the manuscript. MJ and SK gave critical opinion on the overall process of the study. KP is the main coordinator of the study, provided administrative support, statistical expertise and assisted in drafting the manuscript with CK and YW. The author(s) read and approved the final manuscript.

Authors’ information

Not applicable.

Corresponding author

Correspondence to Kok Peng Ng.

Ethics declarations

Ethics approval and consent to participate

This study was approved by the Medical Ethics Committee of UMMC in accordance with the Helsinki Declaration under MECID number 2019818-7752. The clinical and research activities being reported are consistent with the Principles of the Declaration of Istanbul as outlined in the ‘Declaration of Istanbul on Organ Trafficking and Transplant Tourism’. Informed consent was obtained from all the living kidney donors of whom all are still under follow up at the University of Malaya Medical Centre (UMMC).

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests. All authors have approved the manuscript and agree with its submission to BMC Nephrology.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Thye, C.K., Lee, Y.W., Jalalonmuhali, M. et al. Creatinine clearance in selection of living kidney donor among the Malaysian population: is it safe?. BMC Nephrol 24, 267 (2023). https://doi.org/10.1186/s12882-023-03057-w

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12882-023-03057-w

Keywords